Handheld high-frequency water-cooled integrated heating machine
Power: 15KW-100KW
Email: Jinrui-sales@jinruihang.com
Product Introduction
Convenient, fast, and accurate
1,The JINRUIHANG handheld transformer is small and lightweight. Its unique waterproof design and materials make it resistant to water splashes. It is also resistant to weak acids, weak alkalis, and high temperatures.
2, After powering on, the power can be precisely adjusted via the main unit panel. The lightweight and sturdy operating handle and detachable shoulder strap improve ease of use for operators. The flexible output connection cable allows for easy and nimble access to workpieces, facilitating convenient operation and improving efficiency.
3,Built-in water cooler, water tank, PLC digital intelligent control, can be pushed and used when powered on. Simple operation and very convenient use.
Product Parameters
Handheld High-frequency Series | Model Specifications | Power | Frequency | Handheld Length | Cooling Water Pressure | Heating Head Weight |
JRH-SZJ15 JRH-SZJ25 JRH-SZJ30 JRH-SZJ40 JRH-SZJ60 JRH-SZJ80 | 15KW 25KW 30KW 40KW 60KW 80KW | 30-80KHZ | 5 meters - 10 meters | 0.15-0.3MPA | 2 KG |
Application Range
◆ Welding of transformer joints and hard alloy saw teeth
◆ Surface heating, coating, and various on-site heating applications
◆ Welding of copper pipes, stainless steel pipes, and pipes to shells; copper pipe welding in air conditioning, refrigeration, and sanitary ware industries
◆ Quenching, annealing, and preheating for laser welding of automotive parts molds 
Previous Page
FAQ
When the power of the induction heating equipment drops abnormally, it may be caused by the following reasons:
1. Unstable power supply voltage
Input voltage fluctuations or poor cable contact can prevent the equipment from maintaining its rated power. The power supply lines and voltage regulator should be checked.
2. Coil aging or damage
Induction coils operating at high temperatures for extended periods are prone to oxidation, cracking, or inter-turn short circuits, reducing electromagnetic conversion efficiency. Regular inspection of the coil condition is necessary.
3. Cooling system malfunction
Blockage of the water cooling pipes, abnormal water pump operation, or poor water quality can cause the equipment to overheat and trigger a forced power reduction. The water passages should be cleaned, and the heat dissipation components should be checked.
4. Abnormal load matching
Changes in workpiece material, size, or position can reduce the electromagnetic coupling efficiency with the coil. Parameters should be readjusted, or the coil design should be optimized.
5. Component aging
Hardware wear and tear, such as capacitor bank capacitance attenuation and IGBT module performance degradation, requires professional instrument testing and replacement of faulty components.
It is recommended to prioritize checking the power supply and cooling system, then gradually proceed to check the load matching and core components. Contact a professional repair technician if necessary.
Inductive coil lifespan too short? 3 ways to extend its life!
The inductive coil is the "heart" of heating equipment, and a short lifespan is often caused by the following problems and improper maintenance:
1. Avoid overheating damage
Long-term high temperatures can cause oxidation and deformation of the coil. Ensure sufficient cooling water flow, regularly clean scale, check for water pipe blockages, and monitor water temperature.
2. Reduce mechanical stress
Frequent disassembly or workpiece collisions can cause coil deformation and cracking. Handle with care during operation, reinforce the connection between the coil and the equipment, and prevent vibration loosening.
3. Regular cleaning and protection
Metal dust and oil stains on the coil surface can cause arc erosion. Clean with a soft cloth after shutdown, and apply a high-temperature insulating coating (such as ceramic paint) if necessary.
Additional tips: Avoid overloading (power should not exceed 90% of the rated value); if the coil is locally blackened or the inter-turn gap is uneven, stop using and repair immediately.
Regular maintenance can extend the coil lifespan by 1-2 times and reduce the risk of equipment downtime!
Induction Heating Equipment "Low Water Alarm" Handling Guide
When the equipment displays a "low water alarm," it indicates that the cooling system cannot meet the demand and requires immediate troubleshooting:
1. Check water source and level
Ensure the water tank is full and refill to the standard line;
Clean the water inlet filter to prevent clogging by impurities.
Test the water pump status
Listen to see if the water pump is running (no sound may indicate motor damage);
Touch the water outlet pipe to check the water flow pressure. Insufficient pressure requires repair or replacement of the water pump.
3. Troubleshoot water pipe abnormalities
Check if the pipe is bent, leaking, or clogged with scale inside (focus on checking the joints);
In an emergency, you can temporarily connect a clean water source to flush the pipes.
4. Calibrate the water level sensor
If the sensor is falsely alarming, turn off the power and wipe off any scale or bubbles on the probe surface;
If it still alarms, the sensor may be damaged and needs to be replaced.
Preventive measures:
Clean the water tank and replace the softened water monthly;
Avoid using hard water containing impurities to reduce scale formation.
If the above steps are ineffective, immediately stop the machine and contact after-sales service. Forcibly starting may burn out the coil or power module!
Troubleshooting and Maintenance Guide for Heated Equipment Cooling System
Cooling system failures can easily lead to equipment overheating, shutdown, or component damage. Common problems and solutions are as follows:
I. Troubleshooting
1. Abnormal Water Circulation
Phenomenon: Abnormal water pump noise, low water output.
Solution: Check the water pump power supply and whether the impeller is stuck. Clean the inlet filter.
2. Overly High Water Temperature
Phenomenon: Water temperature >50℃.
Solution: Check if the radiator fan is running, clean the radiator fins of dust, and ensure good ventilation.
3. Water Quality Issues
Phenomenon: Pipe blockage, sensor false alarm.
Solution: Replace with softened water, and regularly descale (acetic acid solution can be used for circulating cleaning).
II. Daily Maintenance
1. Weekly Inspection: Water pipe joint sealing to prevent leakage;
2. Monthly Maintenance : Empty the water tank and scrub the inner walls, replace antifreeze (winter);
3. Quarterly Inspection: Water pump bearing lubrication, radiator fan motor carbon brush wear.
Precautions:
After shutdown, be sure to drain the water in the pipes to prevent freezing and cracking at low temperatures;
If frequent alarms occur, check the PLC control module or flow meter calibration.
Regular maintenance can reduce cooling failures by more than 80%, ensuring efficient equipment operation!
Company Advantages
Providing induction heating process solutions for global customers
Providing customers with high-quality and efficient induction heating application solutions
Original manufacturer, strong production capacity, rich experience
We have rich application technology knowledge, independent research and development design, expert design team, combined with our extensive testing and analysis capabilities, is the basis for us to always provide high-quality solutions, we can customize according to your needs.
Let the quality live up to the price, strict quality control
In terms of quality control, we strictly implement the ISO9001:2015 quality management system standard and the safety standardized enterprise management system to ensure that the output equipment meets international quality standards
Quality Service
The company has a professional after-sales service team, 7 x 24 hours customer service, quick response!
Hotline:
Cooperative customers
We have a professional after-sales service team, providing 7x24 hours customer service, ensuring that we can quickly respond to customer needs and problems. Whether it is equipment installation and commissioning, maintenance or technical consultation, we will wholeheartedly provide customers with high-quality service experience.
Related Products
Inquire Now
If you are interested in our products, please leave a message, and we will contact you as soon as possible!