  • 焊接铜管接头mp4(1).mp4
  • 高频25KW 正面.webp
  • 英文版高频 应用.jpg
  • 高频25KW 正侧面.webp
  • 高频25KW 后面.webp
  • 高频25KW 细节图.webp

High-frequency induction machine

Power: 15-25KW



Product Introduction

Product Features 
◆Select the power supply according to the power and frequency. The higher the frequency, the shallower the heating depth; the lower the frequency, the better the heat penetration. 
◆Power: 15-80KW 
◆Frequency: 30-100KHZ 
 

Product Parameters

High-Frequency Equipment SeriesModel SpecificationsOperating Power SupplyVoltage RangeOutput PowerOscillation FrequencyHeating Current
JRH-15ASingle-phase 220V180-250V15KW30-80KHZ200-600A
JRH-25AThree-phase 380V340-430V25KW30-80KHZ200-1200A
JRH-25AB25KW30-80KHZ
JRH-30AB30KW30-80KHZ400-1300A
JRH-35AB35KW30-80KHZ400-1600A
JRH-40AB40KW30-80KHZ400-1800A
JRH-60AB60KW30-80KHZ400-2400A
JRH-80AB80KW30-80KHZ400-3200A

 

Application Range: 
◆One model for multiple purposes, suitable for heating (hot forging, hot fitting, melting of metals through high-temperature heating) 
◆Heat treatment quenching (various hardware tools, gears, auto parts, mold surface quenching); 
◆Welding (brazing, silver soldering, copper soldering through high-temperature heating of metals); 
◆Annealing (annealing of various stainless steel and other metal materials), etc. 
◆Melting, hot fitting, hot forming, heat penetration. 

 

 

FAQ


Q Induction heating equipment power drop? It may be these 5 reasons 2025-04-28 18:29:21.618
A

When the power of the induction heating equipment drops abnormally, it may be caused by the following reasons:

1. Unstable power supply voltage
Input voltage fluctuations or poor cable contact can prevent the equipment from maintaining its rated power. The power supply lines and voltage regulator should be checked.

2. Coil aging or damage
Induction coils operating at high temperatures for extended periods are prone to oxidation, cracking, or inter-turn short circuits, reducing electromagnetic conversion efficiency. Regular inspection of the coil condition is necessary.

3. Cooling system malfunction
Blockage of the water cooling pipes, abnormal water pump operation, or poor water quality can cause the equipment to overheat and trigger a forced power reduction. The water passages should be cleaned, and the heat dissipation components should be checked.

4. Abnormal load matching
Changes in workpiece material, size, or position can reduce the electromagnetic coupling efficiency with the coil. Parameters should be readjusted, or the coil design should be optimized.

5. Component aging
Hardware wear and tear, such as capacitor bank capacitance attenuation and IGBT module performance degradation, requires professional instrument testing and replacement of faulty components.

It is recommended to prioritize checking the power supply and cooling system, then gradually proceed to check the load matching and core components. Contact a professional repair technician if necessary.

Q Short lifespan of induction coils? How to properly maintain the coils of induction heating equipment? 2025-04-28 18:28:43.910
A

Inductive coil lifespan too short? 3 ways to extend its life!

The inductive coil is the "heart" of heating equipment, and a short lifespan is often caused by the following problems and improper maintenance:


1. Avoid overheating damage
Long-term high temperatures can cause oxidation and deformation of the coil. Ensure sufficient cooling water flow, regularly clean scale, check for water pipe blockages, and monitor water temperature.

2. Reduce mechanical stress
Frequent disassembly or workpiece collisions can cause coil deformation and cracking. Handle with care during operation, reinforce the connection between the coil and the equipment, and prevent vibration loosening.

3. Regular cleaning and protection
Metal dust and oil stains on the coil surface can cause arc erosion. Clean with a soft cloth after shutdown, and apply a high-temperature insulating coating (such as ceramic paint) if necessary.

Additional tips: Avoid overloading (power should not exceed 90% of the rated value); if the coil is locally blackened or the inter-turn gap is uneven, stop using and repair immediately.

Regular maintenance can extend the coil lifespan by 1-2 times and reduce the risk of equipment downtime!

Q Troubleshooting: Induction heating equipment shows low water level upon startup? 2025-04-24 19:13:51.238
A

Induction Heating Equipment "Low Water Alarm" Handling Guide

When the equipment displays a "low water alarm," it indicates that the cooling system cannot meet the demand and requires immediate troubleshooting:

1. Check water source and level

Ensure the water tank is full and refill to the standard line;

Clean the water inlet filter to prevent clogging by impurities.

Test the water pump status

Listen to see if the water pump is running (no sound may indicate motor damage);

Touch the water outlet pipe to check the water flow pressure. Insufficient pressure requires repair or replacement of the water pump.

3. Troubleshoot water pipe abnormalities

Check if the pipe is bent, leaking, or clogged with scale inside (focus on checking the joints);

In an emergency, you can temporarily connect a clean water source to flush the pipes.

4. Calibrate the water level sensor

If the sensor is falsely alarming, turn off the power and wipe off any scale or bubbles on the probe surface;

If it still alarms, the sensor may be damaged and needs to be replaced.

Preventive measures:

Clean the water tank and replace the softened water monthly;

Avoid using hard water containing impurities to reduce scale formation.

If the above steps are ineffective, immediately stop the machine and contact after-sales service. Forcibly starting may burn out the coil or power module!

Q Troubleshooting and maintenance methods for induction heating equipment cooling systems 2025-04-24 19:08:16.641
A

Troubleshooting and Maintenance Guide for Heated Equipment Cooling System

Cooling system failures can easily lead to equipment overheating, shutdown, or component damage. Common problems and solutions are as follows:

I. Troubleshooting

1. Abnormal Water Circulation

Phenomenon: Abnormal water pump noise, low water output.

Solution: Check the water pump power supply and whether the impeller is stuck. Clean the inlet filter.

2. Overly High Water Temperature

Phenomenon: Water temperature >50℃.

Solution: Check if the radiator fan is running, clean the radiator fins of dust, and ensure good ventilation.

3. Water Quality Issues

Phenomenon: Pipe blockage, sensor false alarm.

Solution: Replace with softened water, and regularly descale (acetic acid solution can be used for circulating cleaning).
 

II. Daily Maintenance

1. Weekly Inspection: Water pipe joint sealing to prevent leakage;

2. Monthly Maintenance : Empty the water tank and scrub the inner walls, replace antifreeze (winter);

3. Quarterly Inspection: Water pump bearing lubrication, radiator fan motor carbon brush wear.

Precautions:

After shutdown, be sure to drain the water in the pipes to prevent freezing and cracking at low temperatures;

If frequent alarms occur, check the PLC control module or flow meter calibration.
Regular maintenance can reduce cooling failures by more than 80%, ensuring efficient equipment operation!

Company Advantages

Company Advantages

Providing induction heating process solutions for global customers

Providing customers with high-quality and efficient induction heating application solutions

Original manufacturer, strong production capacity, rich experience

We have rich application technology knowledge, independent research and development design, expert design team, combined with our extensive testing and analysis capabilities, is the basis for us to always provide high-quality solutions, we can customize according to your needs.

Company Advantages
Company Advantages

Let the quality live up to the price, strict quality control

In terms of quality control, we strictly implement the ISO9001:2015 quality management system standard and the safety standardized enterprise management system to ensure that the output equipment meets international quality standards

Quality Service

The company has a professional after-sales service team, 7 x 24 hours customer service, quick response!

Quality Service

Cooperative customers


We have a professional after-sales service team, providing 7x24 hours customer service, ensuring that we can quickly respond to customer needs and problems. Whether it is equipment installation and commissioning, maintenance or technical consultation, we will wholeheartedly provide customers with high-quality service experience.

Partner clients
Partner clients
Partner clients
Partner clients
Partner clients
Partner clients
Partner clients
Partner clients
Partner clients
Partner clients
Partner clients
Partner clients
< 1 >

Inquire Now

If you are interested in our products, please leave a message, and we will contact you as soon as possible!

Security verification
Submit